Setting Output - Example Scenario Summary
From the Main Setup display, proceed to the Set Output display by clicking the Set Output button. This display is used to specify the
detector interface type , combine phases into vehicle presence relays, and then route them to output detector channels. After setting up
the output relay signals, return to the Main Setup display by clicking the Main button.
The following list provides a summary of several SVS-1 Output setup examples which are shown in the slides that follow.
1) Type-170 Detector/Controller Interface with 4 Relays per SVS-1 card and 3 Phases (Line Zone Groups)
Phase 1L, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge F
Phase 6T, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge W
Phase 6R, Detection Delay=2 sec, Detection Extension=0, Route to Card Edge W
2) Type-170 Detector/Controller Interface with 2 Relays per SVS-1 card and 3 Phases (Line Zone Groups)
Phase 1L, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge F
Phase 6T, Detection Delay=0 sec, Detection Extension=0, Route to Card Edge W
Phase 6R, Detection Delay=2 sec, Detection Extension=0, Route to Card Edge W
3) BIU #1 Card file Detector/Controller Interface with 4 Relays per SVS-1 card, Slot 2 used, and 3 Phases (Line Zone Groups)
Phase 3L, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D1
Phase 8T, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D2
Phase 8R, Detection Delay=2 sec, Detection Extension=2, Route to Detector Channel D2